Specification guide

Understanding CMM accuracy

Read length error and probing specifications, work through a real catalog example, and ask the right acceptance questions.

Practical application guide · Examples are illustrative unless identified as catalog data.

The key idea

A published MPE is a permissible error limit under specified test conditions. It is not a prediction of the error in every part measurement.

Length measurement and probing answer different questions

The PeakMerit catalog uses MPEe for maximum permissible length measurement error and MPEp for probing performance evaluated using a reference sphere. Read them together with the measuring mode, configuration and applicable test procedure. A probing specification should not be treated as the length error of the whole machine.

A reference length artifact on supports on the left, and a small ruby stylus contacting a large reference sphere on the right.
Length measurement

Compare a measured length with a known reference.

Probing performance

Evaluate probing using a reference sphere.

Concept illustration · These are different checks. The artwork does not show a prescribed test procedure, test result or scale relationship.

TermWhat to look for
MPEeThe length-dependent error formula and the unit used for L.
MPEpThe probing error limit, sphere test procedure and stylus configuration.
Measuring modeThe separate scanning or touch-trigger specification for the exact model.
Sources & further readingNPL Good Practice Guide 42: CMM verification (2011) ↗

Worked example: Gemini 565 in scanning mode

The published Gemini 565 scanning entry lists MPEe = (0.9 + L/300) µm and MPEp = 1.1 µm, with L in millimeters. For a 300 mm measured length, substitute 300 into the length formula:

This 1.9 µm value is the catalog length-error limit at that length, not a measured result or a part-specific uncertainty. The example uses scanning-mode data; the touch-trigger entry has different values. Gemini is intended for a controlled quality room. Confirm the temperature limits, temperature variation, probe and stylus setup, and acceptance procedure in the final quotation and acceptance documentation; those conditions cannot be inferred from this calculation.

The table is arithmetic from the published formula, not measured test results. Enter L in millimeters; the resulting limit is in micrometers. The calculation does not establish performance at every location, orientation or stylus arrangement.

0.9 + 300/300 = 1.9 µm · L = 300 mm
Illustrative measured lengthSubstitutionCalculated MPEe limit
100 mm0.9 + 100/3001.23 µm (rounded)
300 mm0.9 + 300/3001.90 µm
500 mm0.9 + 500/3002.57 µm (rounded)
Sources & further readingPeakMerit: Gemini model specifications ↗

Apply the number to a drawing review

For an illustrative 300 mm dimension on a customer drawing, record 1.9 µm as the catalog comparison value for this model in scanning mode. Next request the measurement method and task-specific uncertainty for that characteristic. Dividing a drawing tolerance by this MPE alone does not establish whether the inspection process is suitable.

Keep the measuring modes separate. The same Gemini 565 entry lists touch-trigger MPEe = (1.6 + L/300) µm, which calculates to 2.6 µm at 300 mm. These are mode-specific catalog limits, not an experimental comparison of two routines on your part. The lower catalog value does not replace an application trial.

Sources & further readingPeakMerit: Gemini configurations ↗

Accuracy, repeatability and uncertainty

Repeatability describes how closely repeated results agree under the same conditions. A measurement process can repeat closely while retaining a systematic error. Measurement uncertainty describes the dispersion reasonably attributed to the measurement result and depends on the particular task. Neither is interchangeable with a catalog MPE.

Part temperature, material expansion, fixturing, stylus reach and measurement strategy all belong in the application review. Compare machines at relevant measurement lengths and under comparable conditions, then agree how the actual inspection requirement will be demonstrated.

Repeatability is only part of the picture

A close grouping does not tell you how close the results are to a reference value.

Tight grouping, with an offset

Reference value
Lower measured valueHigher measured value

Repeated results are close together, but displaced from the reference. Tight repeatability can coexist with bias.

Wider grouping, around the reference

Reference value
Lower measured valueHigher measured value

Results fall on both sides of the reference, with more variation between repeats.

Where uncertainty fitsMeasurement uncertainty is task-specific. It is neither just the spread of these dots nor the catalog MPE.
Conceptual data · Both plots use the same horizontal scale. Each dot represents a repeated result; vertical placement only separates dots visually. No units or machine performance are implied.
  • Identify the exact model and probing mode.
  • Check the required length and probing specifications separately.
  • Confirm environmental and probe-configuration conditions.
  • Agree the acceptance method and task-specific evidence.
Sources & further readingNPL: CMM task-specific measurement uncertainties ↗

Turn the comparison into an acceptance brief

Prepare two deliverables: evidence that the supplied CMM meets its agreed specification, and evidence that your planned measurement process is suitable for the part. Use the drawing and intended fixture to define the second deliverable before commissioning.

Formal test reports can use more detailed symbols than a product table. Request the relevant ISO 10360 part and edition, the tested configuration and the definition of each reported quantity. Do not assume that every number headed 'accuracy' was established by the same test.

Two complementary tracks for acceptance

Connect machine verification with evidence for the work you actually need to measure.

CMM specification

Model · measurement mode · test conditions

↓
Agreed verification reportEvidence against the specified machine requirements.

Your part

Drawing · fixture · measurement strategy

↓
Task-specific suitability evidenceEvidence for the required features and tolerances.
↓↓
Agreed acceptance criteriaReview both evidence tracks against criteria defined before acceptance.
Evidence map · Machine verification and part suitability answer different questions. Agree the scope, conditions and required evidence with the supplier.
  • Name the model, probe, stylus arrangement, controller and software configuration.
  • Record the length and probing limits with their test methods and conditions.
  • Identify critical drawing characteristics and how each will be demonstrated.
  • Request the test report, reference-artifact traceability and uncertainty information.
  • Agree how results close to a tolerance limit will be accepted or rejected.
  • Document checks and review intervals to use after installation.

In this guide

01Length measurement and probing answer different questions02Worked example: Gemini 565 in scanning mode03Apply the number to a drawing review04Accuracy, repeatability and uncertainty05Turn the comparison into an acceptance brief

Continue with your application

Explore the next step

See Gemini model specifications↗Compare CMM families↗Discuss your measurement requirement↗

Keep learning

More measurement essentials

Measurement methodsTouch-trigger or scanning?→Workflow walkthroughCalibration ball scanning demo→
PEAKMERITTECHNOLOGY

CMM systems, probing packages, controllers, and retrofit solutions for manufacturers, quality labs, and metrology distributors.

Direct-manufacturer value with U.S.-based commercial support.

About PeakMerit →

  • Application-FocusedRight machine for your parts
  • Defined SpecificationsModel and probing configuration
  • Complete SolutionsMachine, probe, controller & more
  • Project SupportApplication review and coordination

CMM Machines

  • Compare CMM Models
  • Pisces Standard CMM
  • Polaris Classic CMM
  • Gemini High-Precision CMM
  • Libra Ultra-Precision CMM
  • Aries Shop-Floor CMM
  • Taurus Gantry CMM

Probing & Controllers

  • Probing & Controllers Overview
  • CZ Series Probe Heads
  • CF20 Touch-Trigger Probes
  • SC Scanning Probes
  • MACC Series Controllers
  • CMM Accessories
  • CMM Upgrade & Retrofit

Resources & Support

  • Measurement Guides
  • Accuracy Comparison
  • Software Compatibility
  • Installation & Training
  • Technical Support

Projects & Partners

  • Project Updates
  • Our Partners
  • Distributor Cooperation

Contact

PeakMerit Technology LLCLos Angeles, California, USA

liu@peakmerittechnology.com
+1 (810) 223-6315

Response within one business day.

Request CMM Quote
© 2026 PeakMerit Technology LLC. All rights reserved.Specifications and accuracy values are confirmed in final quotation and acceptance documentation.Privacy settings|Privacy Policy|Terms of Use