PEAKMERIT · ZEISS · HEXAGON

Comparable published accuracy.Significantly lower pricing.

Published CMM accuracy, side by side. Compare four ranges by formula, temperature and probing mode, with each source alongside.

View the comparisons ↓

Compare by CMM range.

Entry-levelPisces 686↓ClassicPolaris 686↓High precisionGemini 686↓Fixed bridgeLibra 686↓
01

Entry-level · Pisces 686

Touch-trigger

Read across to compare → Swipe sideways on smaller screens.

Selected catalog length-error limits. Models are columns; each row compares one attribute. Different probes, travel and acceptance setups; not a common-condition test.
Selected
configuration
PeakMeritPisces 686Touch-triggerHexagonGLOBAL LiteTouch-trigger
Catalog length-error limitµm · L in mmLower limit = tighter specification2.6 + L/300MPEeFrom 1.9 + L/300MPE(E0/E150)*
At L = 300 mmCalculated, not measuredLower limit = tighter specification3.600 µmFrom 2.900 µm
Stated temperature18–22°C18–22°C
Measuring travelX × Y × Z · mm600 × 800 × 600Listed family sizes from 700 × 700 × 500 (07.07.05)
Probing setupCZ10T-S head + CF20 touch-trigger probe; acceptance stylus defined in the technical proposal.Touch-trigger probe. The cited specifications page does not identify the acceptance probe model or stylus.
Source
Source →
Source ↗
02

Classic · Polaris 686

Read across to compare → Swipe sideways on smaller screens.

Selected catalog length-error limits. Models are columns; each row compares one attribute. Different probes, travel and acceptance setups; not a common-condition test.
Selected
configuration
PeakMeritPolaris 686ScanningZEISSCONTURA active 7/7/6ScanningArchived · 2021-05HexagonGLOBAL S Scan+ 05.07.05Scanning
Catalog length-error limitµm · L in mmLower limit = tighter specification1.4 + L/300MPEe1.5 + L/350E0/E1501.5 + L/333MPE(E0/E150)*
At L = 300 mmCalculated, not measuredLower limit = tighter specification2.400 µm2.357 µm2.401 µm
Stated temperature18–22°C18–22°C18–22°C
Measuring travelX × Y × Z · mm600 × 800 × 600700 × 700 × 600500 × 700 × 500
Probing setupScanning catalog entry; sensor, head and acceptance stylus defined in the technical proposal.VAST XT gold · acceptance stylus 60 mm / Ø8 mm tip.Standard package · HP-S-X3 · 60 mm stylus / Ø5 mm tip.
Source
Source →
Source ↗
Source ↗
03

High precision · Gemini 686

Read across to compare → Swipe sideways on smaller screens.

Selected catalog length-error limits. Models are columns; each row compares one attribute. Different probes, travel and acceptance setups; not a common-condition test.
Selected
configuration
PeakMeritGemini 686ScanningZEISSPRISMO 7/9/5ScanningHexagonGLOBAL S Scan+ 07.07.05Scanning
Catalog length-error limitµm · L in mmLower limit = tighter specification1.0 + L/300MPEe1.2 + L/350E0/E1501.2 + L/350MPE(E0/E150)*
At L = 300 mmCalculated, not measuredLower limit = tighter specification2.000 µm2.057 µm2.057 µm
Stated temperature18–22°C18–22°C18–22°C
Measuring travelX × Y × Z · mm600 × 800 × 600700 × 900 × 500700 × 700 × 500
Probing setupScanning catalog entry; sensor, head and acceptance stylus defined in the technical proposal.VAST gold · acceptance stylus 60 mm / Ø8 mm tip (p. 4).Accuracy+ package · HP-S-X3 · 60 mm stylus / Ø5 mm tip.
Other source limitsDifferent metric or temperature—
E0/E150 · 19–21°C0.9 + L/350 µm1.757 µm at 300 mm
—
Source
Source →
Source ↗
Source ↗
04

Fixed bridge · Libra 686

Scanning

Read across to compare → Swipe sideways on smaller screens.

Selected catalog length-error limits. Models are columns; each row compares one attribute. Different probes, travel and acceptance setups; not a common-condition test.
Selected
configuration
PeakMeritLibra 686ScanningZEISSPRISMO ultra 7/10/5ScanningHexagon / LeitzReference HP 7.7.5ScanningArchived · 2015-7
Catalog length-error limitµm · L in mmLower limit = tighter specification0.6 + L/500MPEe0.5 + L/500E00.7 + L/400E0
At L = 300 mmCalculated, not measuredLower limit = tighter specification1.200 µm1.100 µm1.450 µm
Stated temperature20 ± 1°C20–22°C19–21°C
Measuring travelX × Y × Z · mm600 × 800 × 600700 × 1,000 × 500700 × 700 × 500
Bridge architectureFixed bridgeMoving bridgeMoving bridge
Probing setupReference catalog package: PH10M plus + SP25; UCC S3 plus / RationalDMIS. Acceptance stylus defined in the technical proposal.VAST gold · acceptance stylus 60 mm / Ø8 mm tip.Leitz scanning system; published E0 applies to specified Leitz styli without extension.
Other source limitsDifferent metric or temperature—
E150 · 20–22°C0.8 + L/500 µm1.400 µm at 300 mm
—
Source
Source →
Source ↗
Source ↗

Choose for your part.

Check the acceptance standard, probe and stylus, room conditions and measurement uncertainty against your tolerance.

Compare the complete proposal: machine, software, installation, training, warranty and acceptance scope. The source documents govern the full specifications.

Read the accuracy guide →

MAKE THE COMPARISON RELEVANT

Start with your tolerance.
Ask for a defined configuration.

Share your drawing, part size, room conditions and preferred software. We’ll help define the machine and acceptance scope for your inspection work.

Review my CMM requirements →
Sources & comparison notes

Selected catalog length-error limits under source-specific conditions; not a common-condition test or evidence of equal overall performance. These are not scanning-form errors or part uncertainty. MPEe, E0 and E150 are retained as published, not assumed interchangeable. Probes, travel and acceptance setups differ.

The 300 mm figures are calculated from the published formulas, not measured. Relative limits can change with measuring length; rounding to 0.001 µm does not imply that level of measurement uncertainty. Range labels describe the PeakMerit lineup, not equivalent competitor classes.

Prepared by PeakMerit from the sources below. Archived entries describe historical configurations; current specifications and U.S. availability are not established. This selection does not cover every current model or the best available configuration. Confirm current specifications and availability with the supplier. Brand names identify products only; no endorsement or affiliation is implied.

Source editions & configuration notes
  • PeakMerit Pisces 686 · Touch-trigger

    PeakMerit Pisces 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: 0.5°C/h; 2°C/24 h; spatial gradient ≤1°C/m. Relative humidity 45–75%.

  • Hexagon GLOBAL Lite · Touch-trigger

    Hexagon GLOBAL Lite specifications ↗
    Web specifications · checked Oct 21, 2026
    Hexagon Nexus · manufacturer website

    *The source qualifies the metric for calibrated test lengths of non-normal-CTE material. Confirm the size-specific limit and probing setup.

  • PeakMerit Polaris 686 · Scanning

    PeakMerit Polaris 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: 1°C/h; 2°C/24 h; spatial gradient 1°C/m. Relative humidity 40–70%.

  • ZEISS CONTURA active 7/7/6 · Scanning

    ZEISS CONTURA specifications ↗
    2021-05 · pp. 2, 6
    Archived manufacturer document · copy hosted by ats.co.il

    Historical named configuration. Current CONTURA family starting figures are different; this is not a claim about the latest configuration. Original accessories and acceptance instructions apply.

  • Hexagon GLOBAL S Scan+ 05.07.05 · Scanning

    Hexagon GLOBAL Scan+ data sheet ↗
    2024-1 · pp. 2, 5
    Manufacturer document · copy hosted by basstool.com

    *The source qualifies this metric for calibrated test lengths of non-normal CTE material. Maximum-part-weight acceptance testing is optional on request.

    Hexagon GLOBAL S travel reference · 2018 data sheet ↗

  • PeakMerit Polaris 686 · Touch-trigger

    PeakMerit Polaris 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: 1°C/h; 2°C/24 h; spatial gradient 1°C/m. Relative humidity 40–70%.

  • Hexagon GLOBAL Classic 07.07.05 · Touch-trigger

    Hexagon GLOBAL Classic brochure ↗
    2019-01 · pp. 6, 8, 11–12
    Archived Russian edition · copy hosted by promgeo.com

    Historical regional brochure (Russian). Non-normal-CTE test-length qualification (*) applies. U.S. configuration and availability are not established.

  • PeakMerit Gemini 686 · Scanning

    PeakMerit Gemini 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: 1°C/h; 2°C/24 h; spatial gradient 1°C/m. Relative humidity 40–70%.

  • ZEISS PRISMO 7/9/5 · Scanning

    ZEISS PRISMO specifications ↗
    2024-10 · pp. 4, 9
    Manufacturer document · copy hosted by ats.co.il

    Original ZEISS accessories and the manufacturer’s acceptance instructions apply. Different formulas apply at 18–22°C and 19–21°C; both are reproduced here.

  • Hexagon GLOBAL S Scan+ 07.07.05 · Scanning

    Hexagon GLOBAL Scan+ data sheet ↗
    2024-1 · pp. 2, 5
    Manufacturer document · copy hosted by basstool.com

    Accuracy+ is a specific scanning package. The source’s non-normal-CTE test-length qualification (*) and optional maximum-part-weight acceptance test apply.

    Hexagon GLOBAL S travel reference · 2018 data sheet ↗

  • PeakMerit Gemini 686 · Touch-trigger

    PeakMerit Gemini 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: 1°C/h; 2°C/24 h; spatial gradient 1°C/m. Relative humidity 40–70%.

  • Hexagon GLOBAL S Chrome 07.07.05 · Touch-trigger

    Hexagon GLOBAL S data sheet ↗
    2018-02 · pp. 5, 9
    Archived manufacturer document · Hexagon web shop

    Historical Chrome package. Non-normal-CTE test-length qualification (*) applies. Current configuration and U.S. availability are not established.

  • PeakMerit Libra 686 · Scanning

    PeakMerit Libra 686 specifications →
    PeakMerit catalog · reviewed Oct 21, 2026
    PeakMerit model page · specifications & environment

    Catalog environment: ≤1°C/h; ≤2°C/24 h; spatial gradient ≤1°C/m. Relative humidity 55–65%.

  • ZEISS PRISMO ultra 7/10/5 · Scanning

    ZEISS PRISMO specifications ↗
    2024-10 · pp. 2, 9
    Manufacturer document · copy hosted by ats.co.il

    Requires the specified reference standard, reference-sphere bending correction and original ZEISS accessories. E150 has a separate limit, shown separately.

  • Hexagon / Leitz Reference HP 7.7.5 · Scanning

    Leitz CMM overview data sheet ↗
    2015-7 · p. 2
    Archived manufacturer document · copy hosted by pvp-snk.ru

    2015 reference only. Probe variant and its stylus exception must be checked in the original footnote. Current U.S. new-machine availability is not established.

PEAKMERITTECHNOLOGY

CMM systems, probing packages, controllers, and retrofit solutions for manufacturers, quality labs, and metrology distributors.

Direct-manufacturer value with U.S.-based commercial support.

About PeakMerit →

  • Application-FocusedRight machine for your parts
  • Defined SpecificationsModel and probing configuration
  • Complete SolutionsMachine, probe, controller & more
  • Project SupportApplication review and coordination

CMM Machines

  • Compare CMM Models
  • Pisces Standard CMM
  • Polaris Classic CMM
  • Gemini High-Precision CMM
  • Libra Ultra-Precision CMM
  • Aries Shop-Floor CMM
  • Taurus Gantry CMM

Probing & Controllers

  • Probing & Controllers Overview
  • CZ Series Probe Heads
  • CF20 Touch-Trigger Probes
  • SC Scanning Probes
  • MACC Series Controllers
  • CMM Accessories
  • CMM Upgrade & Retrofit

Resources & Support

  • Measurement Guides
  • Accuracy Comparison
  • Software Compatibility
  • Installation & Training
  • Technical Support

Projects & Partners

  • Project Updates
  • Our Partners
  • Distributor Cooperation

Contact

PeakMerit Technology LLCLos Angeles, California, USA

liu@peakmerittechnology.com
+1 (810) 223-6315

Response within one business day.

Request CMM Quote
© 2026 PeakMerit Technology LLC. All rights reserved.Specifications and accuracy values are confirmed in final quotation and acceptance documentation.Privacy settings|Privacy Policy|Terms of Use